EU Standard · Three-phase
16 kW / 16 kVA three-phase hybrid inverter, 1000 V DC input, 32 kWp PV over 2 MPPT, 32 kVA surge, AFCI + RSD + ISO protection, 150% unbalanced load.
The DOGO DG16K-TP-EU is the high-voltage member of the three-phase range: 1000 V DC input, 32 kWp of PV across two trackers and 300 A of PV charging. High string voltage cuts cable losses on long commercial roofs.
It carries AFCI arc-fault detection, RSD rapid shutdown and ISO insulation monitoring as standard, plus 150% unbalanced load capability so a single phase can be fully loaded without tripping. Three-phase independent CT anti-backflow keeps export at zero per phase rather than in aggregate.
| Model | DG16K-TP-EU |
|---|---|
| Grid Standard | EU — 230/400 Vac three-phase, 50/60 Hz |
| Phase | Three-phase |
| Rated AC Output Power | 16 kW |
| Max AC Output Power | 16 kVA |
| Peak Power (5 s) | 32 kVA |
| Rated Output Voltage | 3L/N/PE 230 / 400 Vac |
| Rated Output Frequency | 50/60 Hz |
| Power Factor | 1 |
| AC Connection | L1 + L2 + L3 + N + PE |
| Max DC Input Power | 32 kWp (16 kW + 16 kW) |
| Max DC Input Voltage | 1000 V |
| Start Voltage | 160 V |
| PV Input Voltage Range | 160–1000 V |
| MPPT Voltage Range | 160–850 V |
| MPPT Channels | 2 |
| Max MPPT Input Current | 36 A + 36 A |
| Max PV Charging Current | 300 A |
| AC Input Range | 170–280 Vac per phase |
| Max AC Input Current | 60 A per phase |
| Max AC Charge Current | 200 A |
| Max Efficiency | >93.5% |
| Rated Battery Voltage | 51.2 Vdc |
| Battery Voltage Range | 40–60 Vdc |
| Battery Type | Lead-acid / Lithium |
| Max Charge / Discharge Current | 300 A / 340 A |
| Charge Voltage Range | 40–58.6 Vdc |
| Generator Input | 3L/N/PE 230/400 Vac, 90–280 Vac, 40–70 Hz, 200 A, 10 ms transfer |
| AFCI | Yes — 12 Vdc / 1 Adc detection loop |
| Grid Overload Protection | Circuit breaker |
| Grid Breaker Rating | 63 A |
| Transfer Time | 10 ms (typical) |
| Parallel Capability | 1–6 units |
| Dimensions (W × D × H) | 720 × 482 × 149 mm |
| Weight | 30 kg |
| Operating Temperature | −10 to +55 °C (derating above 45 °C) |
| Storage Temperature | −25 to +60 °C |
| Humidity Range | 5%–95% |
| Cooling Method | Forced air cooling (variable speed) |
| Protection Class | IP21 |
| Noise | ≤ 60 dB |
| Altitude | 4000 m (no derating to 2000 m) |
| Safety / EMC Certification | CE (IEC 62109-1/-2) | IEC 61000, C2 |
| Communication Ports | USB / RS485 / WiFi |
| Dry Contact Control | Yes |
| Battery-less Operation | Yes |
| Remote Monitoring / OTA | Yes |
| CT Anti-backflow | Three-phase independent CT anti-backflow |
| Special Functions | AFCI + RSD + ISO triple protection; 150% unbalanced load capacity |
Values are typical at 25°C unless otherwise stated. Full test report available on request.