US Standard · Split-phase
10 kW split-phase hybrid inverter for 120/240 Vac US grids. 12 kWp PV over 2 MPPT, 15 kVA surge, 220 A discharge, 23.5 kg wall-mount chassis.
The DOGO DG10K-SP-US delivers 10 kW per leg into a 120/240 Vac split-phase panel, with 15 kVA of surge for compressor and well-pump starts. PV input reaches 12 kWp across two trackers at 22 A each.
Battery current is 220 A in both directions, so a 30 kWh bank can absorb midday surplus and return it in the evening without throttling. The chassis measures 620 × 450 × 132 mm and weighs 23.5 kg.
| Model | DG10K-SP-US |
|---|---|
| Grid Standard | US — 120/240 Vac split-phase, 60 Hz |
| Phase | Split-phase |
| Rated AC Output Power | 10 kW |
| Max AC Output Power | 7.2 kW per 120 V leg (max unbalanced) |
| Peak Power (5 s) | 15 kVA |
| Rated Output Voltage | 120/240 Vac |
| Rated Output Frequency | 50/60 Hz |
| Power Factor | 1 |
| AC Connection | L1 + L2 + N + PE |
| Max DC Input Power | 12 kWp (6 kW + 6 kW) |
| Max DC Input Voltage | 500 V |
| Start Voltage | 120 V |
| PV Input Voltage Range | 90–500 V |
| MPPT Voltage Range | 90–450 V |
| MPPT Channels | 2 |
| Max MPPT Input Current | 22 A + 22 A |
| Max PV Charging Current | 220 A |
| AC Input Range | 85–140 Vac per phase |
| Max AC Input Current | 60 A per phase |
| Max AC Charge Current | 120 A |
| Max Efficiency | >93.5% |
| Rated Battery Voltage | 51.2 Vdc |
| Battery Voltage Range | 40–60 Vdc |
| Battery Type | Lead-acid / Lithium |
| Max Charge / Discharge Current | 220 A / 220 A |
| Charge Voltage Range | 40–60 Vdc |
| Grid Overload Protection | Circuit breaker |
| Grid Breaker Rating | 63 A |
| Transfer Time | 10 ms (typical) |
| Parallel Capability | 1–6 units |
| Dimensions (W × D × H) | 620 × 450 × 132 mm |
| Weight | 23.5 kg |
| Operating Temperature | −10 to +55 °C (derating above 45 °C) |
| Storage Temperature | −25 to +60 °C |
| Humidity Range | 5%–95% |
| Cooling Method | Forced air cooling (variable speed) |
| Protection Class | IP21 |
| Noise | ≤ 60 dB |
| Altitude | 4000 m (no derating to 2000 m) |
| Safety / EMC Certification | UL 1741 / CSA C22.2#107.1 | FCC Part 15 Class B |
| Communication Ports | USB / RS485 / WiFi / CAN |
| Dry Contact Control | Yes |
| Battery-less Operation | Yes |
| Remote Monitoring / OTA | Yes |
| CT Anti-backflow | Yes |
Values are typical at 25°C unless otherwise stated. Full test report available on request.