US Standard · Split-phase
8 kW split-phase hybrid inverter for 120/240 Vac US grids. 2 MPPT with 10 kWp PV input, 12 kVA surge, 180 A discharge and up to 6 units in parallel.
The DOGO DG8K-SP-US doubles the PV side of the 6 kW model: two MPPT trackers of 5 kWp each, 18 A per tracker, on the same 120/240 Vac split-phase output. It is the usual size for a US home with a 10 kWp roof and a 20 kWh battery.
Surge capability is 12 kVA per phase, and up to six units parallel for larger properties. The 51.2 V battery port accepts 160 A charge and 180 A discharge, with CAN available for closed-loop BMS control.
| Model | DG8K-SP-US |
|---|---|
| Grid Standard | US — 120/240 Vac split-phase, 60 Hz |
| Phase | Split-phase |
| Rated AC Output Power | 8 kW |
| Max AC Output Power | 6 kW per 120 V leg (max unbalanced) |
| Peak Power (5 s) | 12 kVA |
| Rated Output Voltage | 120/240 Vac |
| Rated Output Frequency | 50/60 Hz |
| Power Factor | 1 |
| AC Connection | L1 + L2 + N + PE |
| Max DC Input Power | 10 kWp (5 kW + 5 kW) |
| Max DC Input Voltage | 500 V |
| Start Voltage | 120 V |
| PV Input Voltage Range | 90–500 V |
| MPPT Voltage Range | 90–450 V |
| MPPT Channels | 2 |
| Max MPPT Input Current | 18 A + 18 A |
| Max PV Charging Current | 160 A |
| AC Input Range | 85–140 Vac per phase |
| Max AC Input Current | 50 A per phase |
| Max AC Charge Current | 120 A |
| Max Efficiency | >93% |
| Rated Battery Voltage | 51.2 Vdc |
| Battery Voltage Range | 40–60 Vdc |
| Battery Type | Lead-acid / Lithium |
| Max Charge / Discharge Current | 160 A / 180 A |
| Charge Voltage Range | 40–60 Vdc |
| Grid Overload Protection | Circuit breaker |
| Grid Breaker Rating | 50 A |
| Transfer Time | 10 ms (typical) |
| Parallel Capability | 1–6 units |
| Dimensions (W × D × H) | 580 × 359 × 127 mm |
| Weight | 15.9 kg |
| Operating Temperature | −10 to +55 °C (derating above 45 °C) |
| Storage Temperature | −25 to +60 °C |
| Humidity Range | 5%–95% |
| Cooling Method | Forced air cooling (variable speed) |
| Protection Class | IP21 |
| Noise | ≤ 60 dB |
| Altitude | 4000 m (no derating to 2000 m) |
| Safety / EMC Certification | UL 1741 / CSA C22.2#107.1 | FCC Part 15 Class B |
| Communication Ports | USB / RS485 / WiFi / CAN |
| Dry Contact Control | Yes |
| Battery-less Operation | Yes |
| Remote Monitoring / OTA | Yes |
| CT Anti-backflow | Yes |
Values are typical at 25°C unless otherwise stated. Full test report available on request.
Send the details below and you will get price, lead time and shipping cost in one reply — usually within one business day.
Prefer to talk? Message us on WhatsApp — +86 180 9640 4273
Send us your load profile, site location and target quantity — we reply within one business day.