🌞 Factory-direct solar & storage — worldwide shipping WhatsApp / WeChat: +86 180 9640 4273
Home/ Products /Inverter /US Standard /Split-phase /DOGO 16kW Split-Phase Hybrid Inverter (US)
DOGO 16kW Split-Phase Hybrid Inverter (US)

US Standard · Split-phase

DOGO 16kW Split-Phase Hybrid Inverter (US)

16 kW split-phase hybrid inverter for 120/240 Vac US grids. 24 kWp PV over 2 MPPT, 24 kVA surge, 300 A charge / 340 A discharge, 37.5 kg.

  • Rated AC Output Power: 16 kW
  • Max DC Input Power: 24 kWp (12 kW + 12 kW)
  • Max Efficiency: >93.5%

The DOGO DG16K-SP-US is the largest split-phase model: 16 kW per leg, 24 kVA surge, and 300 A / 340 A battery current on a 51.2 V bus. It covers a whole-home back-up with EV charging on the same panel.

Two MPPT trackers accept 24 kWp at 36 A each — enough for a 20–25 kWp roof on a single inverter. Grid breaker rating is 100 A, and up to six units parallel for estate-scale installations.

Technical Specifications

DOGO 16kW Split-Phase Hybrid Inverter (US) — Technical Specifications
Model DG16K-SP-US
Grid Standard US — 120/240 Vac split-phase, 60 Hz
Phase Split-phase
Rated AC Output Power 16 kW
Max AC Output Power 9.6 kW per 120 V leg (max unbalanced)
Peak Power (5 s) 24 kVA
Rated Output Voltage 120/240 Vac
Rated Output Frequency 50/60 Hz
Power Factor 1
AC Connection L1 + L2 + N + PE
Max DC Input Power 24 kWp (12 kW + 12 kW)
Max DC Input Voltage 500 V
Start Voltage 120 V
PV Input Voltage Range 90–500 V
MPPT Voltage Range 90–450 V
MPPT Channels 2
Max MPPT Input Current 36 A + 36 A
Max PV Charging Current 300 A
AC Input Range 85–140 Vac per phase
Max AC Input Current 90 A per phase
Max AC Charge Current 200 A
Max Efficiency >93.5%
Rated Battery Voltage 51.2 Vdc
Battery Voltage Range 40–60 Vdc
Battery Type Lead-acid / Lithium
Max Charge / Discharge Current 300 A / 340 A
Charge Voltage Range 40–60 Vdc
Grid Overload Protection Circuit breaker
Grid Breaker Rating 100 A
Transfer Time 10 ms (typical)
Parallel Capability 1–6 units
Dimensions (W × D × H) 720 × 482 × 149 mm
Weight 37.5 kg
Operating Temperature −10 to +55 °C (derating above 45 °C)
Storage Temperature −25 to +60 °C
Humidity Range 5%–95%
Cooling Method Forced air cooling (variable speed)
Protection Class IP21
Noise ≤ 60 dB
Altitude 4000 m (no derating to 2000 m)
Safety / EMC Certification UL 1741 / CSA C22.2#107.1 | FCC Part 15 Class B
Communication Ports USB / RS485 / WiFi / CAN
Dry Contact Control Yes
Battery-less Operation Yes
Remote Monitoring / OTA Yes
CT Anti-backflow Yes

Values are typical at 25°C unless otherwise stated. Full test report available on request.

Request a quotation

Send the details below and you will get price, lead time and shipping cost in one reply — usually within one business day.

  • Target quantity and destination port or city
  • Grid type and system voltage at the site
  • Required backup hours, if this is a storage project

Prefer to talk? Message us on WhatsApp — +86 180 9640 4273

We reply by email or WhatsApp. Your details are not shared.

Need a spec sheet or a factory price?

Send us your load profile, site location and target quantity — we reply within one business day.

✆