US Standard · Split-phase
6.2 kW split-phase hybrid inverter for 120/240 Vac US grids. 6.2 kW total, 4.8 kW on a single 120 V leg, 9.3 kVA surge, 9 kWp PV input, UL 1741 and FCC Part 15 Class B.
The DOGO DG6K-SP-US produces 120/240 Vac split-phase output on L1 + L2 + N + PE, so it wires straight into a North American load centre without a transformer. Each leg carries 6.2 kW, with 9.3 kVA available for five seconds.
A single MPPT accepts 9 kWp at up to 500 V, and the 51.2 V battery port handles 120 A charge and 140 A discharge. UL 1741 / CSA C22.2#107.1 listing and FCC Part 15 Class B emission apply.
| Model | DG6K-SP-US |
|---|---|
| Grid Standard | US — 120/240 Vac split-phase, 60 Hz |
| Phase | Split-phase |
| Rated AC Output Power | 6.2 kW |
| Max AC Output Power | 4.8 kW per 120 V leg (max unbalanced) |
| Peak Power (5 s) | 9.3 kVA |
| Rated Output Voltage | 120/240 Vac |
| Rated Output Frequency | 50/60 Hz |
| Power Factor | 1 |
| AC Connection | L1 + L2 + N + PE |
| Max DC Input Power | 9 kWp |
| Max DC Input Voltage | 500 V |
| Start Voltage | 120 V |
| PV Input Voltage Range | 90–500 V |
| MPPT Voltage Range | 90–450 V |
| MPPT Channels | 1 |
| Max MPPT Input Current | 27 A |
| Max PV Charging Current | 120 A |
| AC Input Range | 85–140 Vac per phase |
| Max AC Input Current | 40 A per phase |
| Max AC Charge Current | 100 A |
| Max Efficiency | >92.5% |
| Rated Battery Voltage | 51.2 Vdc |
| Battery Voltage Range | 40–60 Vdc |
| Battery Type | Lead-acid / Lithium |
| Max Charge / Discharge Current | 120 A / 140 A |
| Charge Voltage Range | 40–60 Vdc |
| Grid Overload Protection | Circuit breaker |
| Grid Breaker Rating | 40 A |
| Transfer Time | 10 ms (typical) |
| Parallel Capability | Not supported |
| Dimensions (W × D × H) | 420 × 330 × 122 mm |
| Weight | 12 kg |
| Operating Temperature | −10 to +55 °C (derating above 45 °C) |
| Storage Temperature | −25 to +60 °C |
| Humidity Range | 5%–95% |
| Cooling Method | Forced air cooling (variable speed) |
| Protection Class | IP21 |
| Noise | ≤ 60 dB |
| Altitude | 4000 m (no derating to 2000 m) |
| Safety / EMC Certification | UL 1741 / CSA C22.2#107.1 | FCC Part 15 Class B |
| Communication Ports | USB / RS485 / WiFi / CAN |
| Dry Contact Control | Yes |
| Battery-less Operation | Yes |
| Remote Monitoring / OTA | Yes |
| CT Anti-backflow | Yes |
Values are typical at 25°C unless otherwise stated. Full test report available on request.
Send the details below and you will get price, lead time and shipping cost in one reply — usually within one business day.
Prefer to talk? Message us on WhatsApp — +86 180 9640 4273
Send us your load profile, site location and target quantity — we reply within one business day.